Chapter 2
Messages and Recovery Procedures
Error Message PLATFORM_ENV-1-EXTERNAL_ALARM_CONTACT_CLEAR: Alarm cleared: [chars]
Explanation
Recommended Action
Error Message PLATFORM_ENV-1-FRU_PS_FAN_FAILED: Faulty PS [chars] fan detected
Explanation
Recommended Action
Error Message PLATFORM_ENV-1-FRU_PS_FAN_OK: PS [chars] fan ok
Explanation
Recommended Action
Error Message PLATFORM_ENV-1-FRU_PS_OIR: FRU Power Supply [chars]
Explanation
Recommended Action
OL-23408-01
An alarm is no longer detected on an external contact. [chars] is the alarm.
No action is required.
Failure detected in the specified power supply fan. [chars] is the fan.
Replace the faulty fan.
The specified power supply fan is working properly. [chars] is the fan.
No action is required.
The specified power supply is inserted or removed. [chars] is the power supply.
No action is required.
Cisco ME 3400E, ME 3400, and ME 2400 Ethernet Access Switch System Message Guide
PLATFORM_ENV Messages
2-33