Firmware Update Procedures - Tascam HS-P82 Release Note

Hs-p82 release note v1.10
Hide thumbs Also See for HS-P82:

Advertisement

Firmware update procedures

CAUTION
When updating the firmware, make sure that there is
sufficient remaining battery charge or use the AC adaptor
included for the unit (TASCAM PS-1225L). If the remaining
battery charge is low, updating the firmware will not be
possible. If a firmware update is interrupted by lack of power,
the unit could become unusable and require service.
1 Download the latest version of the firmware from
the TASCAM website (http://tascam.com/).
2 Insert a CF card only in COMPACT FLASH SLOT 1
and turn the unit power on.
CAUTION
You should only insert a CF card in COMPACT FLASH SLOT 1.
You cannot update using COMPACT FLASH SLOT 2. Do not
insert a card into slot 2 in order to avoid transferring the file
to it accidentally.
3 Press the MENU key to open the
4 Touch the
CF/USB MANAGE
screen.
USB MANAGE
5 Touch the
item's
CF SELECT
open the
screen.
CF SELECT
6 Touch the
item's
CF1
CF CARD
CF card in COMPACT FLASH SLOT 1. When selected,
the
background becomes yellow.
CF 1
7 Touch the
button to return to the
SET
screen.
MANAGE
8 Connect the unit with a computer using the USB
cable.
9 If the
CF/USB MANAGE
the MENU key to open the
the
button to open the
CF/USB MANAGE
screen.
MANAGE
10 Touch the
item's
USB
CONNECT
11 When the
Touch OK to Enable to USB
appears in a pop-up window, touch the
CAUTION
When connected, the "USB mode Enabled. Touch CLOSE to
end" message pop-up window is displayed. Do not touch the
"CLOSE" button while connected.
12 Copy the downloaded firmware to the CF card in
COMPACT FLASH SLOT 1 of the HS-P82.
NOTE
When using Windows, two "HS-P82" icons appear on the
computer screen. Copy the firmware to the root folder of
the "HS-P82" that is labeled closer to "A" alphabetically.
When using a Mac, if a CF card is inserted only in
COMPACT FLASH SLOT 1, only one "HS-P82" icon should
appear. Copy the file to this one.
13 When copying is complete, follow the proper
procedures to disconnect this unit from the
computer.
screen.
MENU
button to open the
CF/
button to
SELECT
button to select the
CF/USB
screen is not open, press
screen, and touch
MENU
CF/USB
button.
message
button.
OK
HS-P82
14 Touch the
CLOSE
Disable USB
button.
15 Turn the unit power OFF.
16 While pressing and holding both the PAUSE and
REC keys at the same time, turn the unit power ON
again.
The unit starts up in update mode and the screen
shows the file for updating.
NOTE
If the above screen is not shown, turn the power OFF once,
and then turn the power ON again while pressing and
holding the PAUSE and REC keys at the same time. Keep
pressing these keys until the above screen is displayed.
The above screen shows a list of firmware update files in
the root folder of the CF card inserted in COMPACT FLASH
SLOT 1. The firmware copied in step 12 above should be
shown. If no update file is in the folder, "No Update File"
appears.
A maximum of five lines of firmware can be shown at
once. If there are more files than this, use the up and down
arrow buttons on the scrollbar at the right side of the
screen or the DATA dial to scroll through the list.
This screen is just an example, and the actual appearance
might be different.
17 Touch the name of the firmware that you want to
use to update the unit.
The following screen is shown.
The current version is shown on the left side and the
version of the update is shown on the right side.
NOTE
This screen is just an example, and the actual appearance
might be different.
Release Notes
button to open a
Touch OK to
pop-up message. Touch the
TASCAM HS-P82
OK
5