V1.02 fixes

That default value of the reference level has been
changed from "–16dB" to "–20dB".
The precision of the
POWER OFF GEN
improved.
The precision of time code capture at the start of
recording has been improved.
The precision of time code output when
is set to
has been improved.
REC RUN
If the display is dimmed completely, touch input is
disabled.
SLATE key was pressed and released at the
When the
same time as another key, the SLATE indicator would
stay lit. This issue has been corrected.
On the
screen, touching an empty line
MARK LIST
when less than four marks were shown would cause
the Home Screen to reopen. This issue has been
corrected.
When set to
file mode, after pressing the
MONO
button on the folder selection screen, the
shown in the pop-up window was inaccurate. This issue
has been corrected.
When moving quickly between project, folder and take
selection screens, the display could become garbled.
This issue has been corrected.
When a channel link was on and the phantom power
setting was changed for those channels, the setting
change was not made for the even-numbered channel.
This issue has been corrected.
When a channel link was on, the remaining time
for
and
shown on the Home Screen was
CF1
CF2
inaccurate. This issue has been corrected.
When a channel set to a digital input was unlocked and
the input setting was changed to analog by turning on
a channel link, the input sound was not unmuted. This
issue has been corrected.
When a CF card was inserted immediately after starting
the unit, or if a CF card was inserted in a slot when the
other slot already had a CF card loaded, the
pop-up window would remain displayed on
Reading
rare occasions. This issue has been corrected.
If a project recorded on a CF card was erased on a
computer, and then rebuilding another project was
conducted on this unit, the rebuilding would not
complete. This issue has been corrected.
If the name of a created folder had 31 characters, the
track name for Ch1 shown beneath the level meters
would be blank. This issue has been corrected.
When backing up settings to a CF card in
FLASH SLOT 2, the file would not be created in some
cases. This issue has been corrected.
Reverse search operation has been improved.
Mark information was not recorded to a CF card in
COMPACT FLASH SLOT 2 in some cases. This issue has
been corrected.
4
TASCAM HS-P82
HS-P82
function has been
TC GEN MODE
INFO
TOTAL TIME

Checking the firmware version

Before conducting a firmware update, check the firmware
version currently installed in your HS-P82.
1 Turn the unit power ON.
2 Press the MENU key on the front panel to open the
3 Press the
Media
COMPACT
Release Notes
When playing back continuous takes created by
pressing the REC key during recording, setting marks
became impossible. This issue has been corrected.
If recording was stopped immediately after starting
with pre-recording, the unit would freeze on rare
occasions. This issue has been corrected.
When Recording with "LR 2MIX" on, more than 999
takes could be created in a folder. This issue has been
corrected.
When the file mode was set to "POLY", if only the "LR
2MIX" was recorded, the unit would freeze. This issue
has been corrected.
When, for example, the time code generator mode was
set to
the
JAM SYNC
POWER OFF GEN
not work properly in some cases. This issue has been
corrected.
If there were more than 100 subfolders and files in a
folder, that folder could not be deleted in some cases.
This issue has been corrected.
In a project with the sampling frequency set to 96
kHz, a part of recording data could be lost on very rare
occasions. This issue has been corrected.
If both channels 1 and 2 were set as digital inputs and
unlocked, the voice memo and slate tone functions did
not work correctly. This issue has been corrected.
When inserting a CF card into a slot, even if it contained
a project,
would be displayed on rare
NO PROJECT
occasions. This issue has been corrected.
screen.