Item
Function
Capacity
Capacity
Total power input
Max. power input
EER or COP
Power cable
Communication cable
Power source
Running / Max.Running current
Start current (system A / system B)
Fuse size (recommended size)
Compressor
Model / Manufacturer
Oil charge and type
Type
Number
Fan
Type × Number
Speed
Motor output power
Air-flows (H/M/L)
Heat exchanger
Type / Diameter
Total face area
Temp. scope
Dimension
External
(L×W×H)
Package
Refrigerant control method
Defrosting method
Crankcase heater power
Noise level
H/M/L
Weight
Net / Shipping
Refrigerant
Type / Charge
No need to recharge
Recharge
Pipe
Liquid
Gas
Connecting method
Between I.D &O.D
Drop between IU & OU
Drop between indoor units
Piping length
Total length
Max.Drop between IU &OU*
Max.Drop between indoor units
Max.Piping length *
Max.Total length *
Note: 1.Nominal condition: indoor temperature (cooling): 27 ℃DB/19℃WB, indoor temperature (heating): 20 ℃DB
Outdoor temperature(cooling): 35 ℃DB/24℃WB, outdoor temperature(heating): 7 ℃DB/6℃WB
2.The noise level will be measured in the third octave band limited values, using a Real Time Analyser calibrated sound
intensity meter. The noise level is measured at 2meter in front of the unit, 1.5 meter high to the ground.
3. * Long piping length and large drop between the indoor and outdoor unit (which exceeds standard value) will obviously
reduce the capacity.
Model
AU84NXTBAA
Cooling
——
88000
BTU/h
26000
W
11000
W
13000
W
2.36
W/W
——
8x(0.75~1.25mm
——
N, V, Hz
A / A
18.0 / 22.0
A
A
C-SBN373H8A / SANYO
——
1700 CC (DAPHNE FV68S)
——
SCROLL (Fix speed)
——
——
——
850±50/720±50
r/min
W
m³/h
TP2M / 9.52x0.35
mm
cooling: 43~60 / heating: 6~7
mm
mm
——
——
W
dB(A)
kg / kg
g
Total piping length less than
m
10meters in one system
g/m
mm
mm
——
m
m
m
m
m
30(outdoor unit upside); 20(outdoor unit down)
m
m
m
-10-
Heating
100000
30000
11000
13000
2.73
4 × 5.0mm
2
)
2
3, 380~400, 50
18.0 / 22.0
30.0 / 30.0
40
2
Axial × 1
600
10000/-/6000
about 1.8
1000/750/1750
1155/925/1870
Capillary tube
Automatic
34*2
60/-/-
161 /185
R407C / 4000*2
65
4*Φ9.52
2*Φ19.05
Flared
≤10 (per way)
≤5
≤15 (per way)
≤60 (4 ways)
5
25 (per way)
100 (4 ways)