Installation Clearances; Model Number Identification - Haier GE Appliances NS18AT Service Manual

Table of Contents

Advertisement

Installation Clearances

See NOTES
See
NOTES
See NOTES

Model Number Identification

APPLICATION
A-AIR CONDITIONER
COOLING CAPACITY
(1000BTU/HR)
PHYSICAL AND ELECTRICAL DATA
Model
Voltage/Hz/Phase
NS18A24T
208-230/60/1
NS18A36T
208-230/60/1
NS18A48T
208-230/60/1
NS18A60T
208-230/60/1
See
NOTES
CONTROL
BOX
N
N S S
18 A A 36
18
BRAND
N-GE
PRODUCT
S-SPLIT
SEER
H-HEAT PUMP
24, 36, 48, 60
Voltage
Range
197-253
197-253
197-253
197-253
NOTES:
Service clearance of 30 in. (762 mm) must be maintained on
one of the sides adjacent to the control box.
Clearance to one of the other three sides must be
36 in. (914 mm)
Clearance to one of the remaining two sides may be
A clearance of 24 in. must be maintained between two units.
48 in. (1219 mm) clearance required on top of unit.
36 T T
A A
4 4
– – XX
XX
Max. Over
Min.
Current
Rated
Circuit
Device
Load
Amp.
(amps)
(amps)
14.6
25
10.9
20.2
35
15.4
26.2
45
19.9
32.2
50
23.7
Page 3
MAJOR / MINOR
REVISION
REFRIGERANT
4-R410A
VOLTAGE
A-208/230 1PH 60HZ
DESIGN VARIANT
T-2 STAGE
Compressor
Outdoor Fan Motor
Locked
Full Load
Rotor
(amps)
(amps)
61
1
92
1
127
1.4
151
2.6
Rated
Nom.
HP
RPM
1/6
825
1/6
825
1/4
825
1/3
825
31-5000747 Rev. 0