Item
Function
Capacity
Capacity
Dehumidifying capacity
Power cable
Communication cable
Power source
Running current
Fan
Heat exchanger
Dimension
(L×W×H)
Drainage pipe
Controller type
Refrigerant control
Fresh air hole dimension
Electricity Heater
Noise level
Weight
Refrigerant
Pipe
Connecting method
Dimension
(L×W×H)
Weight
Item
Function
Capacity
Capacity
Dehumidifying capacity
Power cable
Communication cable
Power source
Running current
Fan
Heat exchanger
Dimension
(L×W×H)
Drainage pipe
Controller type
Refrigerant control
Fresh air hole dimension
Electricity Heater
Noise level
Weight
Refrigerant
Pipe
Connecting method
Dimension
Weight
* o.d.=outer diameter; i.d.=inner diameter
Model
——
BTU/h
10‐³×m³/h
——
——
N, V, Hz
Type × Number
——
Speed
r/min
Motor output power
Air-flows (H/M/L)
m³/h
Type / Diameter
Total area
Temp. scope
External
Package
material, diameter
——
——
——
H/M/L
dB(A)
Net / Shipping
kg / kg
Type
——
Liquid
Gas
——
External
Package
Net / Shipping
kg / kg
Model
——
BTU/h
10‐³×m³/h
——
——
N, V, Hz
Type × Number
——
Speed
r/min
Motor output power
Air-flows (H/M/L)
m³/h
Type / Diameter
Total area
Temp. scope
External
Package
material, diameter
——
——
——
H/M/L
dB(A)
Net / Shipping
kg / kg
Type
——
Liquid
Gas
——
External
Package
Net / Shipping
kg / kg
AB072XCBAA
Cooling
Heating
7000
8000
W
2000
2300
1.0
2x(0.75~1.25mm
A
0.20
0.20
CENTRIFUGAL × 1
750/610/540
W
40
650/580/550
mm
TP2M / 9.52×0.8
about 0.25
cooling: 6~7 / heating: 43~60
mm
700×570×276
mm
775×715×361
mm
PVC, 32/26(o.d./I.d.*)
Phone type infrared controller or Wired controller
mm
100
/
45/40/35
24/26
R407C
mm
6.35
mm
12.7
Flared
mm
630×630×80
mm
680×680×155
4.2/6.3
AB122XCBAA
Cooling
Heating
12000
13000
W
3500
3900
1.6
2x(0.75~1.25mm
A
0.20
CENTRIFUGAL × 1
750/610/540
W
40
650/580/550
mm
TP2M / 9.52×0.8
about 0.25
cooling: 6~7 / heating: 43~60
mm
700×570×276
mm
775×715×361
mm
PVC, 32/26(o.d./I.d.*)
Phone type infrared controller or Wired controller
mm
100
/
45/40/35
26/28
R407C
mm
6.35
mm
12.7
Flared
mm
630×630×80
mm
680×680×155
4.2/6.3
-13-
AB092XCBAA
Cooling
9000
2600
/
1.0
3 × (1.0~1.5mm
)
2
)
2
1, 220~230, 50
0.20
CENTRIFUGAL × 1
750/610/540
40
650/580/550
TP2M / 9.52×0.8
about 0.25
700×570×276
775×715×361
PVC, 32/26(o.d./I.d.*)
Capillary tube
100
/
45/40/35
24/26
R407C
6.35
12.7
Flared
630×630×80
680×680×155
4.2/6.3
AB142XCBAA
Cooling
14000
4100
/
1.6
3 × 0.75mm
2
)
2
1, 220~230, 50
0.20
0.20
CENTRIFUGAL × 1
750/610/540
40
650/580/550
TP2M / 9.52×0.8
about 0.25
700×570×276
775×715×361
PVC, 32/26(o.d./I.d.*)
Capillary tube
100
/
45/40/35
26/28
R407C
6.35
12.7
Flared
630×630×80
680×680×155
4.2/6.3
Heating
10000
2900
/
0.20
Heating
16000
4600
/
0.20