RAID level
Logical disks
Configuration
options:
Cabinet
RAID arrays
Number and mix of
cabinets
Rack Storage/12:
Model
Disk drives:
Cables
Rack Storage/8:
Model
Disk drives:
Cables
1, 5, 10, 50
1 per RAID array
8 maximum per NetRAID-3Si adapter
Cluster mode on
Cache write-policy to Write thru
Set bus speed for Rack Storage/8 to Ultra
Set any other options as you prefer
A RAID array (logical disk) must be composed of all the same disk model
(i.e., part number and suffix). Different size or speed disks are not
allowed in the same RAID array. Any combination of disk models is
allowed on a SCSI channel and in a cluster.
1 – 3, any mix of RackStorage/12s and Rack Storage/8s.
D5989A and 1 D6025A for each Rack Storage/12 (350-450 MHz, Nova 1)
D5989B and 1 D6025B for each Rack Storage/12 (400-450 MHz, Nova 2)
HP 4.2 GB Ultra SCSI Disk Module D6104A
HP 9.1 GB Ultra SCSI Disk Module D6106A
HP 9.1 GB (10k rpm) Ultra SCSI Disk Module D6107A
HP 18.2 GB Ultra SCSI Disk Module D6108A
HP 18.2 GB (7200 rpm) Low Profile Ultra SCSI Disk Module D7174A
HP 36.4 GB (10k rpm) Ultra SCSI Disk Module D8210A
Any 2 HP LVD SCSI cables from the following list:
1 meter D7131A
2.5 meter D6020A
5 meter D6982A
10 meter D6983A
D4902A
HP 4.2 GB Ultra SCSI Disk Module D3583C
HP 4.2 GB (10k rpm) Ultra SCSI Disk Module D4903A
HP 9.1 GB Ultra SCSI Disk Module D4289A
HP 9.1 GB (10k rpm) Ultra SCSI Disk Module D6019A
HP 18.2 GB Ultra SCSI Disk Module D5039A
NOTE All disks in a Rack Storage/8 must be the same speed.
HP D5957A Cluster Adapter (2 required per HP Rack Storage/8)
NOTE If both channels 0 and 2 of the NetRAID Adapter are used, then
cable D7131A must be used with Cluster Adapter D5957A on both
channels.