Chapter 1
3. Double-click on the entry to examine the Event Detail dialog box. The
upper half of the box gives a short generic description of the error. The
lower half of the box is a hex and ASCII dump of error data.
4. Scroll through the error data in ASCII for any readable strings.
5. If a readable string is present, it will describe the problem in more detail.
6. If no readable string is present, this typically indicates that the driver failed
early in the process of loading-usually due to a resource conflict (for
example, an I/O port conflict).
NOTE
Make sure the Network Adapter is connected to a working hub
and verify that the LED is lit. Otherwise, the Network Driver
may not install.

Tip #6. Booting from Another PCI SCSI HDD

To boot Windows NT from another SCSI hard disk, press Ctrl-A during system
boot to enter SCSI-Select menu. In this menu, configure the SCSI Hard Drive
Priority option (in the Boot Device Ordering menu. For most Adaptec SCSI
controllers the "Extended Translation option" can be enabled from SCSI-Select is
available by.

On-Line Information and Software Sources

HP NetServer World Wide Web access: http://netserver.hp.com/netserver/
Microsoft World Wide Web access: http://www.microsoft.com
Microsoft Product Support Services: http://support.microsoft.com/directory/
Windows NT Automated Database: Advanced Systems at (800) 936-4400
Microsoft Software BBS: 206-936-6735 (14,400 bps)
8