HP StorageWorks 2/8-EL - SAN Switch Release Note page 21

V. 3.1.x
Hide thumbs Also See for StorageWorks 2/8-EL - SAN Switch:
Table of Contents

Advertisement

Web tools, Java Bug
If a dialog box is displayed from the switch admin window of the Web Tools and
the user selects another dialog box from Web Tools, a Windows display error
results.
This display error is a known defect in Java 1.3. The issue is documented at the
following location:
To avoid the display error, open only one dialog box at a time or launch another
switch admin session in a separate window.
Zoning
To use Zoning in a non-RCS (Reliable Commit Service) mode fabric (in a fabric
containing switches with a firmware version other than v2.6.1x, v3.1.x and
v4.1.x), it is recommended that all appropriate Zoning licenses be installed on all
the switches in the fabric before attempting to bring a switch into the fabric.
Additionally, if the Zoning license has been removed, the user must make sure it is
re-installed properly on the affected switch before attempting a cfgenable
zoning operation. Failure to follow these steps can cause inconsistency of Zoning
configuration on the affected switches should a zoning operation be attempted
from a remote switch in the fabric. On the affected switches, an error message
appears on the console or Telnet session, indicating that the zoning license is
missing.
Note:
or errDump command.
Loop Devices
Some loop devices do not link up to the fabric. This problem occurs when the
switch does not send enough LIPs to transitions from the AL-PA sequence to the
the OLD_Port sequence.
To avoid the issue, set the port as a G-Port by using the portCfgGPort
command.
SAN Switch 2/8 Version 3.1.x Release Notes
http://java.sun.com/
You can also see the error message by performing either the errShow
Issues and Workarounds
(bug ID 4763605).
21

Advertisement

Table of Contents
loading

Table of Contents