STEP-1 Setting of the Operation Configuration

■ Optical axis setting

Set the optical axis.
Confirm the position of optical axis and set it by PIXCEL figure (Number of pixels).
X figure : Set the horizontal position on the screen. (adjustable range is 0 - 1024)
Y figure : Set the vertical position on the screen. (adjustable range is 0 - 768)
Upper left side is X=0, Y=0 position.
Setting example:
When the optical axis is at the center both horizontally and vertically.
X figure = 1024/2 =512, Y figure = 768/2=384.
When the optical axis is 30% from left sid and 70% from a upper side;
X figure = 1024 x 0.3=307, Y figure = 768 x 0.7=537.