Brocade Communications Systems SN3000B Administrator's Manual page 88

Network monitoring software
Hide thumbs Also See for SN3000B:
Table of Contents

Advertisement

7
portThConfig command procedures
TABLE 18
Area
Signal loss
Sync loss
Protocol errors (PE)
Received packets
(RXP)
State changes (ST)
Transmitted packets
(TXP)
Trunk utilization
(E_Port, FCU_Port,
and FOP_Port)
Link reset
66
FOP_Port and FCU_Port class default settings (Continued)
Description
Monitors the
number of signal
loss errors.
Monitors the
number of loss of
synchronization
errors.
Monitors the
number of primitive
sequence errors.
Monitors the receive
rate, by percentage.
Monitors state
changes.
Monitors the
transmit rate, by
percentage.
The percent of
utilization for the
trunk at the time of
the last poll.
Monitors the
number of link
resets sent by a
given port (LR-Out)
and received on a
given port (LR-In).
Default threshold
Default alarm settings
settings
Unit: Errors
Below: 0
Time Base: minute
Above: 0
Low: 0
High: 5
Buffer: 0
Unit: Errors
Below: 0
Time Base: minute
Above: 0
Low: 0
High: 500
Buffer: 50
Unit: Errors
Below: 0
Time Base: minute
Above: 0
Low: 0
High: 5
Buffer: 0
Unit: Percentage (%)
Below: 0
Time Base: minute
Above: 0
Low: 0
High: 100
Buffer: 0
Unit: Changes
Below: 0
Time Base: minute
Above: 0
Low: 0
High: 50
Buffer: 0
Unit: Percentage (%)
Below: 0
Time Base: minute
Above: 0
Low: 0
High: 100
Buffer: 0
Unit: Percentage (%)
Below: 0
Time Base: minute
Above: 0
Low: 0
High: 100
Buffer: 0
Unit: Errors
Below: 0
Time Base: minute
Above: 0
Low: 0
High: 500
Buffer: 50
Threshold state
Informative
Out_of_range
Informative
Out_of_range
Informative
Out_of_range
Informative
Informative
Informative
Out_of_range
Informative
Informative
Informative
Informative
Informative
Out_of_range
Fabric Watch Administrator's Guide
53-1002153-02

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fabric watch

Table of Contents