HP P6000 Installation Manual page 16

Enterprise virtual array
Hide thumbs Also See for P6000:
Table of Contents

Advertisement

2.
Perform one of the following, depending on whether the IQN was listed.
a.
If the iSCSI initiator IQN is listed, enter the index number of the initiator. Then, enter 0
(zero) to enable CHAP, and enter the CHAP secret as shown in the CLI example.
b.
If the iSCSI initiator IQN is not listed, you can use either the CLI or HP P6000 Command
View to add the iSCSI initiator IQN.
3.
Enable CHAP for the iSCSI or iSCSI/FCoE port using HP P6000 Command View or the CLI.
If using HP P6000 Command View:
a.
b.
c.
If using the CLI to enable CHAP for the iSCSI or iSCSI/FCoE port:
a.
b.
c.
d.
4.
Enable CHAP for the iSCSI or iSCSI/FCoE presented target. To enable CHAP for the Discovered
iSCSI Initiator entry using the CLI:
a.
Enter the set chap command.
b.
Select the presented target to which the initiator will log in.
c.
Enable CHAP and enter a CHAP secret. For example: hpstorageworks.
16
Reviewing and confirming your plans
Using the initiator add command with the CLI:
MEZ75 (admin) #> initiator add
A list of attributes with formatting and current values will follow.
Enter a new value or simply press the ENTER key to accept the current value.
If you wish to terminate this process before reaching the end of the list
press 'q' or 'Q' and the ENTER key to do so.
Initiator Protocol (0=ISCSI, 1=FC, 2=FCOE) [ISCSI ] 0
Only valid iSCSI name characters will be accepted. Valid characters include
lower-case alphabetical (a-z), numerical (0-9), colon, hyphen, and period.
iSCSI Initiator Name (Max = 223 characters) [ ] iqn.1991-05.com.microsoft.perf2.sanbox.com
OS Type (0=Windows, 1=Linux, 2=Solaris,
3=OpenVMS, 4=VMWare, 5=Mac OS X,
6=Windows2008, 7=HP-UX, 8=AIX,
9=Other) [Windows ] 6
All attribute values that have been changed will now be saved.
Using HP P6000 Command View: Add the initiator IQN using the Add Host function
(select Hosts in the Navigation pane, and then select Add Host).
Choose the appropriate iSCSI or iSCSI/FCoE controller, select the IP Ports tab, and
then select the appropriate IP port.
Under Security, select Enabled in CHAP Status, then type in the CHAP secret. For
example: hpstorageworks
Click the Save Changes tab to save the changes.
Enter the set chap command.
Select the appropriate Portal IQN name index to which the initiator will log in.
Select 0 to enable CHAP.
Enter a CHAP secret. For example: hpstorageworks.