Pc Adjust Status Read Command; Cr_Fsync Command; Cr_Tdots Command; Cr_Clamp Command - Sanyo PLC-XU305A - 3000 Manual

Expand serial command functional specifications
Hide thumbs Also See for PLC-XU305A - 3000:
Table of Contents

Advertisement

PLC-XU305A/355A Expand Serial Command Functional Specifications

9.5 PC Adjust Status Read Command

9.5.1

CR_FSYNC Command

Command
"CR_FSYNC"[CR]
Details
Get Fine Sync value
Acceptable
%a
Response
Unacceptable
9.5.2

CR_TDOTS Command

Command
"CR_TDOTS"[CR]
Details
Get Total Dots value
Acceptable
%a
Response
Unacceptable
9.5.3

CR_CLAMP Command

Command
"CR_CLAMP"[CR]
Details
Get Clamp value
Acceptable
%a
Response
Unacceptable
9.5.4
CR_H – POS Command
Command
"CR_H
Details
Get Horizontal Position value
Acceptable
%a
Response
Unacceptable
"000_%a"[CR]
"0000"~"0031"
"Error Code"[CR] ----- When the command is invalid due to
"?"[CR] -------------------- When unclear command is received
"000_%a"[CR]
"nnnn"~"mmmm"
(nnnn = Display Dots + Horizontal Position)
(mmmm= Maximum value depends on input signal)
"Error Code"[CR] -------- When the command is invalid due to
"?"[CR] ----------------------- When unclear command is received
"000_%a"[CR]
"0001"~"nnnn"
("nnnn" depends on input signal)
"Error Code"[CR] -------- When the command is invalid due to
"?"[CR] ----------------------- When unclear command is received
-
POS"[CR]
"000_%a"[CR]
"0000"~"nnnn"
(nnnn = Total Dots - Display Dots)
"Error Code"[CR] -------- When the command is invalid due to
"?"[CR] ----------------------- When unclear command is received
47/68
condition such as Input source
condition such as Input source
condition such as Input source
condition such as Input source

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Plc-xu355aPlc-xu305a