Cf_Hscale Command; Cf_Hpos Command - Sanyo PLC-XU305A - 3000 Manual

Expand serial command functional specifications
Hide thumbs Also See for PLC-XU305A - 3000:
Table of Contents

Advertisement

PLC-XU305A/355A Expand Serial Command Functional Specifications
8.7.7

CF_HSCALE Command

Command
"CF_HSCALE_%1"[CR]
"032" --------- +32
"031" --------- +31
ÿ
"002" --------- +2
"001" --------- +1
"000" --------- +0
%1
"-01" ---------- -1
"-02" ---------- -2
ÿ
"-31" ---------- -31
"-32" ---------- -32
"UP" ---------- Horizontal Scale setting value + 1
"DN" ---------- Horizontal Scale setting value - 1
Set Horizontal Scale
This command is available in normal Power ON status.
Note1) When Screen setting is not in Custom mode, projector changes image
Details
mode into Custom by receiving this command.
Note2) When there is no signal detected, projector returns 101 and the command
does not execute.
Acceptable
Response
Unacceptable
8.7.8

CF_HPOS Command

Command
"CF_HPOS_%1"[CR]
"015" --------- +15
"014" --------- +14
ÿ
"002" --------- +2
"001" --------- +1
"000" --------- +0
%1
"-01" ---------- -1
"-02" ---------- -2
ÿ
"-14" ---------- -14
"-15" ---------- -15
"UP" ---------- Horizontal Position setting value + 1
"DN" ---------- Horizontal Position setting value - 1
Set Horizontal Position
This command is available in normal Power ON status.
Note1) When Screen setting is not in Custom mode, projector changes image
Details
mode into Custom by receiving this command.
Note2) When there is no signal detected, projector returns 101 and the command
does not execute.
Acceptable
Response
Unacceptable
"000"[CR]
"Error Code"[CR]
"000"[CR]
"Error Code"[CR]
30/68

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Plc-xu355aPlc-xu305a

Table of Contents