Reset To Factory Default Settings - Axis P5522 User Manual

Ptz dome network camera
Table of Contents

Advertisement

AXIS P5522 PTZ Dome Network Camera
System Options
Uploaded files are accessed through http://<ip address>/local/<user>/<file name> where <user> is the
selected user group (viewer, operator or administrator) for the uploaded file.
Plain Config
Plain Config is for advanced users with experience of Axis product configuration. All parameters can be set and modified from this
page. Help is available from the standard help pages.
To open Plain Config, go to System Options > Advanced > Plain Config.

Reset to factory default settings

This will reset all parameters, including the IP address, to the factory default settings:
1. Press and hold the Control button and the Restart button at the same time (see Hardware overview, on page 4 ).
2. Release the Restart button but continue to hold down the Control button for about 15 seconds until the Status indicator
flashes amber.
3. Release the Control button. The process is complete after about 1 minute (when the Status indicator turns green). The
product has been reset to the factory default settings. The default IP address is 192.168.0.90
4. Re-assign the IP address.
It is also possible to reset parameters to factory default via the web interface. Go to Setup > System Options > Maintenance.
46

Advertisement

Table of Contents
loading

Table of Contents