Table F-1
Specifications (continued)
Rated Input Current
1
This system utilizes an active power factor corrected power supply. This allows the system to pass the CE mark
requirements for use in the countries of the European Union. The active power factor corrected power supply also has the
added benefit of not requiring an input voltage range select switch.

t200 Specifications

Table F-2
t200 Zero Client
Dimensions
Width (side to side)
Height (without mounting bracket)
Height (with mounting bracket)
Depth (front to back)
Approximate Weight
Without mounting bracket
With mounting bracket
Temperature Range *
Operating**
(max. rate of change is 10° C per hour or 18° F per hour)
Nonoperating
(max. rate of change is 20° C per hour or 36° F per hour)
*Specifications are at sea level with altitude derating of
1° C/300m (1.8° F/1000ft) to a maximum of 3Km
(10,000ft), with no direct, sustained sunlight. Upper limit
may be limited by the type and number of options
installed.
Relative Humidity (non-condensing)
Operating
(max. wet bulb temperature is 28° C or 84.2° F)
Nonoperating
(max. wet bulb temperature is 38.7° C or 101.6° F)
Maximum Altitude (unpressurized)
Operating
(max. allowed rate of change is 457 m per minute or 1500
ft per minute)
Nonoperating
(max. allowed rate of change is 457 m per minute or 1500
ft per minute)
4A
136 mm
35 mm
41 mm
91 mm
343 g
381 g
10° to 40° C
-30° to 60° C
** The operating temperature range when the t200
Zero Client is attached to a flat panel using the
mounting bracket is 50° to 95° F (10° to 35° C).
10–90%
5–95%
3,048 m
9,144 m
5.35 in.
1.38 in
1.61 in
3.58 in.
12.1 oz
13.44 oz
50° to 104° F
-22° to 140° F
10–90%
5–95%
10,000 ft
30,000 ft