Status Read Command; Format; Transfer Example; Operation Requirements - Sanyo PLC-HP7000L Specifications

Rs232c basic
Hide thumbs Also See for PLC-HP7000L:
Table of Contents

Advertisement

PLC-HP7000L Basic Serial Command Functional Specifications
7

Status Read Command

7.1 Format

・ PC issues a command in the following format.
"CR" Command [CR]
Command: one character (See Status Read Command Table)
・ When projector receives an appropriate command, it returns the required data in string.
Required Data [CR]
Required Data: string (See Status Read Command Table)
When the received data cannot be decoded, the projector returns "?" [CR] is returned.

7.2 Transfer Example

Information for Input mode of projector can be obtained by Basic Commands.
PC → Projector
Projector → PC

7.3 Operation Requirements

Status Read commands are invalid when projector is in standby and "Eco" mode selected in
Standby mode menu.
Command (issue current input mode command)
"C" "R"
"1" CR
(A few
(Indicating Computer 1 is selected)
22/27
"1"
CR
←―――→ Response
)
ms - 5 s