Control Timer Values (Sec); Vertical Service Activation Codes - Linksys SPA921-NA Administrator's Manual

900 series
Table of Contents

Advertisement

Regional Tab

Control Timer Values (sec)

Field
Reorder Delay
Call Back Expires
Call Back Retry Intvl
Call Back Delay
VMWI Refresh Intvl
Interdigit Long Timer
Interdigit Short Timer

Vertical Service Activation Codes

Vertical Service Activation Codes are automatically appended to the dial-plan. There is
need to include them in dial-plan, although
Field
Call Return Code
Linksys 900 Series IP Phone Administrator Guide
5-22
Description
Delay after far end hangs up before reorder tone is played. 0 = plays immediately,
inf = never plays. Range: 0–255 seconds.
The default is 5.
Expiration time in seconds of a call back activation. Range: 0–65535 seconds.
The default is 1800.
Call back retry interval in seconds. Range: 0–255 seconds.
The default is 30.
Delay after receiving the first SIP 18x response before declaring the remote end
is ringing. If a busy response is received during this time, the 900 Series phone
still considers the call as failed and keeps on retrying.
The default is 0.5.
Interval between VMWI refresh to the CPE.
The default is 0.5.
Long timeout between entering digits when dialing. The interdigit timer values
are used as defaults when dialing. The Interdigit_Long_Timer is used after any
one digit, if all valid matching sequences in the dial plan are incomplete as dialed.
Range: 0–64 seconds.
The default is 10.
Short timeout between entering digits when dialing. The Interdigit_Short_Timer
is used after any one digit, if at least one matching sequence is complete as dialed,
but more dialed digits would match other as yet incomplete sequences. Range:
0–64 seconds.
The default is 3.
Description
This code calls the last caller.
The default is *69.
Chapter 5
SPA900 Series Phone Field Reference
harm is done if they are included.
no
no
Document Version 3.0

Advertisement

Table of Contents
loading