6. Connect the mini SAS signal cables to the RAID controller.
Note: Use the 400 mm (15.75 inches) mini SAS signal cable.
Figure 48. Connecting the mini SAS signal cables to the RAID controller
1
Ports 0-3
2
Ports 4-7
a. For one mini SAS signal cable, connect the end to the ports 0-3 on the RAID controller.
b. For the other mini SAS signal cable, connect the end to the ports 4-7 on the RAID controller.
7. Position the RAID controller near the riser card assembly. Ensure that the left edge of the RAID controller
is inserted into the notch of the RAID card retention bracket
straight down into the PCI card slot 1
RAID controller.
Figure 49. Installing the RAID controller into the PCI card slot 1 on the riser card assembly
Note: There are three PCI card slots on the riser card assembly as shown in the illustration. The PCI
card slot 1
2
is for RAID cards only. For more information about the PCI card slots, see "Installing a
PCI card" on page 39.
8. Install the riser card assembly with the RAID controller into an appropriate PCI card slot on the system
board.
1
2
until it is securely seated. Then install the screw
Chapter 5
, and then firmly insert the RAID controller
.
Installing, removing, or replacing hardware
3
to secure the
55