Multilink PPP Commands

The following table describes the MLPPP configuration commands.
AT%M1=n
AT%M2=n
AT%M3=n
AT%M4=n
AT%P5=n
AT%P6=n
AT%P7=n
Local Endpoint Discriminator Class. The value for 'n' specifies the Local Endpoint
Discriminator Class. If you specify n=1 (class 1), the Local Endpoint Discriminator
Address (specified with AT%M3=n) must be an even number. For a list of classes, see
"Endpoint Discriminator Class/Address" on page 48.
Remote Endpoint Discriminator Class. The value for 'n' specifies the Remote
Endpoint Discriminator Class. For a list of classes, see "Endpoint Discriminator
Class/Address" on page 48.
Local Endpoint Discriminator Address. The value for 'n' specifies the Local
Endpoint Discriminator Address. For a description of permitted addresses, see
"Endpoint Discriminator Class/Address" on page 48.
Remote Endpoint Discriminator Address. The value for 'n' specifies the Remote
Endpoint Discriminator Address. For a description of permitted addresses, see
"Endpoint Discriminator Class/Address" on page 48.
Bandwidth Allocation Control Protocol (BACP) / Bandwidth on Demand (BOD).
This command specifies whether BACP/BOD is enabled or disabled. When enabled,
the DIVA T/A will drop to one B channel (reducing costs) when throughput drops
below 64K. The DIVA T/A first attempts to negotiate BACP; if this is unsuccessful, the
DIVA T/A falls back to BOD.
n=0 Disable (default).
n=1 Enable.
Note: You can use this parameter only if the DIVA T/A has been configured for MLPPP.
Set Initial Billing Interval Timer. Sets the timer (in seconds) to match the amount of
time your ISDN provider allocates as the first time interval.
Note: If the value is set to 0, the timer is not used. Setting this value to 0, also
effectively sets AT%P7 to 0.
Range: 0 to 65535.
Default: 60 seconds.
Set Billing Interval Timer. Sets the timer (in seconds) to match the amount of time
your ISDN provider designates as the minimum chargeable unit for all subsequent
billing.
Note: If the value is set to 0, the timer is not used.
Range: 0 to 65535.
Default: 60 seconds.