2. Select SEQ1 and then press the [HOME/SET] button.
The SEQ1 SETUP menu shown in the figure appears on
the monitor screen.
SEQ1(SPOT-SEQUENCE)SETUP 1 OF 2
AUTO SKIP
DWELL TIME 2SEC
STEP CAM PRE TIME
1
1CH
-
2
2CH
-
3
3CH
-
4
4CH
-
5
5CH
-
6
6CH
-
7
7CH
-
8
8CH
-
Auto Skip
1. Move the cursor to the AUTO SKIP parameter.
2. Select either ON or OFF.
ON: Enables the auto skip function.
OFF: Disables the auto skip function.
The factory default setting is OFF.
Note: The auto skip function is not available when play-
ing back videotape images.
Image Assignment
1. Move the cursor to the CAM column you want to edit for
the step number by pressing the C, D, A or B button.
2. Select the desired camera or playback channel in the
CAM column by pressing the - or + button.
1 - 16: Camera Channel
P1 - P16: Playback Channel
–: Not Assigned
Notes:
• Pressing the Camera Number button assigns the
camera channel directly.
• Any playback steps programmed in a sequence are
excluded from display on the spot monitor and mul-
tiscreen 2 monitor due to the way the system is
designed.
3. Repeat steps 1 and 2 above to assign other steps.
Preset Position
1. Move the cursor to the PRE column you want to edit for
the step number by pressing the C, D, A or B button.
38
OFF
STEP CAM PRE TIME
2SEC
9
9CH
-
2SEC
2SEC
10 10CH
-
2SEC
2SEC
11 11CH
-
2SEC
2SEC
12 12CH
-
2SEC
2SEC
13 13CH
-
2SEC
2SEC
14 14CH
-
2SEC
2SEC
15 15CH
-
2SEC
2SEC
16 16CH
-
2SEC
2. Select the desired preset position number for the cam-
era in the PRE column by pressing the - or + button.
Note: A preset position assigned to a step that has
been assigned to a playback channel is invalid.
3. Repeat steps 1 and 2 above to assign other steps.
Dwell Time
• Uniform Dwell Time
1. Move the cursor to the DWELL TIME parameter by
pressing the C or D button.
2. Select the desired dwell time by pressing the A or
B button.
Dwell Time can be selected between 0SEC and
30SEC.
Note: If 0SEC is selected for the dwell time, the
spot sequence is not activated.
• Individual Dwell Time
1. Move the cursor to the TIME column you want to
edit for the step number by pressing the C, D, A
or B button.
2. Select the desired dwell by pressing the - or +
button.
Steps for which a different dwell time has been
selected are marked "–" in the DWELL TIME para-
meter. Previous settings made in the DWELL TIME
parameter become invalid.
Programming Steps 17 to 32
1. Press the [FUNCTION] button to display the next page
of the table.
The table shown in the figure appears on the monitor
screen.
SEQ1(SPOT-SEQUENCE)SETUP 2 OF 2
STEP CAM PRE TIME
17
-
-
2SEC
18
-
-
2SEC
19
-
-
2SEC
20
-
-
2SEC
21
-
-
2SEC
22
-
-
2SEC
23
-
-
2SEC
24
-
-
2SEC
2. Program the sequence pattern for steps 17 to 32 as
described previously.
3. Press the [FUNCTION] button to display the previous
page of the table.
STEP CAM PRE TIME
25
-
-
2SEC
26
-
-
2SEC
27
-
-
2SEC
28
-
-
2SEC
29
-
-
2SEC
30
-
-
2SEC
31
-
-
2SEC
32
-
-
2SEC

Advertisement