Dell PowerEdge C6145 Using Instructions page 58

Using the baseboard management controller
Hide thumbs Also See for PowerEdge C6145:
Table of Contents

Advertisement

 
GET LAN
OEM2 14h
SOURCE
GET FCB FW
oem2
VERSION
SET FAN
oem2
CONTROL
GET FAN
oem2
CONTROL
IPMI OEM Command List
|
Request:
Response:
Byte 1 – completion code
Byte 2 – Current LAN Source
00h – Shared NIC
01h – Dedicated NIC
16H
Request:
Response:
Byte 1 – completion code
Byte 2 – FCB Fw Major number
Byte 3 – FCB Fw Minor number
61H
Request:
Byte 1 – Fan Control Setting
[7] – Enabled/Disabled FAN Control
0: Disabled(Default)
1: Enabled
[6:0] – Duty Cycle Setting. The rage is
from 0 to 100, others are reserved.
Response:
Byte 1 – completion code
62H
Request:
Response:
Byte 1 – completion code
Byte 2 – Fan Control Setting
[7] – Enabled/Disabled FAN Control
0: Disabled(Default)
1: Enabled
[6:0] – Duty Cycle Setting. The rage is
from 0 to 100, others are reserved.
 
58