AMX DAS-M-0404 Operation/Reference Manual page 81

Mi series distributed audio controllers
Hide thumbs Also See for DAS-M-0404:
Table of Contents

Advertisement

RS-232 Controller Command Messages (Cont.)
MARGgg,r
MRRGr
MDRG
MGRGr
MIGVr,i
MDGVr,i
MSGVr,v
MGRSs
MSFVr,s,f
MGFVr,s
MSLOr
MCLOr
MGLO
MSPSs,n,p
Mi Series Audio Controllers
Add Room to Group, where:
• 'g' is any room already in the group, (1-64)
• 'r' is the room, (1-64)
Remove Room from Group, where:
'r' is the room to remove, (1-64)
Note: The Room Grouping will be removed if less than 2 rooms
are associated with the given source.
Dissolve all Room Groupings
Get Room Grouping, where:
'r' is any room in the grouping, (1-64)
Increment the Volume for a Room Grouping, where:
• 'r' is any room in the grouping, (1-64)
• 'i' is the increment value or 0 for system default
Decrement the Volume for a Room Grouping, where:
• 'r' is any room in the grouping
• 'i' is the decrement value or 0 for system default
Set the Volume for a Room Grouping, where:
• 'r' is any room in the grouping
• 'v' is the desired volume level, valid values are:
101: Mute
0...55: 0...-55 dB
Get the Rooms currently listening to a source, where:
's' is the desired source, (1-8)
Set the favorite, where:
• 'r' is the desired room, (1-64)
• 's' is the desired source, (1-8)
• 'f' is the direct tuning string; it can be from 0 to 7 characters long
and is translated as specified in the 'Send Source Direct Data'
command: Zero length data will clear the favorite.
Get the favorite, where:
• 'r' is the desired room, (1-64)
• 's' is the desired source, valid values are 1-8
Lock out the keypad in a room, where:
'r' is the room to lock out, (1-64)
Clear the keypad lock out in a room, where:
'r' is the room to clear the lock out in, (1-64)
Get the keypad lock out status for the system.
Set the preset, where:
• 's' is the desired source, (1-8)
• 'n' is the desired preset, (1-10)
• 'p' is the direct tuning string; it can be from 0 to 7 characters long
and is translated as specified in the 'Send Source Direct Data'
command: Zero length data will clear the preset
RS-232 Commands / Messages
Room Grouping Status
- or -
ERR
Room Grouping Status
- or -
ERR
ACK
- or -
ERR
Room Grouping Status
- or -
ERR
ACK
- or -
ERR
ACK
- or -
ERR
ACK
- or -
ERR
Source Grouping Status
- or -
ERR
Favorite Status
- or -
ERR
Favorite Status
- or -
ERR
Lock Out Status
- or -
ERR
Lock Out Status
- or -
ERR
Lock Out Status
- or -
ERR
Preset Status
- or -
ERR
71

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents