Download Print this page

Maytag MGR5775QDW - 30 Inch Gas Range Installation Manual page 6

Gas 30-inch wide free-standing range
Hide thumbs Also See for MGR5775QDW - 30 Inch Gas Range:

Advertisement

RecommendedGas SupplyConnections
a.
FLEXIBLE
3/8"
SUPPLY
STREET
LINE
ELBOW
/
1/2" NPT MALE TO 3/8" NPT FEMALE-- k
_7
ADAPTER BUSHING
"_
BEGU TOB
VALVE
FLEXIBLE
j_SUPPLY
LINE
1/2"NPT MALETO 3/8"NPT FEMALE--_
ADAPTER BUSHING'_
REG0 TOR
REGULATOR_-___
SHUT-OFF
OFF
VALVE
FIG URE 3
WHEN THE INSTALLER HAS COMPLETED
INSTALLATION OF THE APPLIANCE,
LEAVE THE
APPLIANCE
PRESSURE REGULATOR SHUT-OFF
VALVE IN THE "ON" POSITION.
A GAS CUTOFF VALVE SHOULD BE PUT IN AN
ACCESSIBLE
LOCATION IN THE SUPPLY LINE
AHEAD OF THE RANGE, FOR TURNING ON AND
TURNING OFF GAS SUPPLY. If range is to be
connected to house piping with flexible or semi-rigid
metal connectors for gas appliances, CONNECTOR
NUTS MUST NOT BE CONNECTED
DIRECTLY TO
PIPE THREADS. THE CONNECTORS
MUST BE
INSTALLED WITH ADAPTORS PROVIDED WITH
THE CONNECTOR.
b,
The house piping and/or range connector used to
connect the range to the main gas supply must be
clean, free of metal shavings, rust, dirt and liquids (oil
or water). Dirt, etc. in the supply lines can work its
way into the range manifold and in turn cause failure
of the gas valves or controls and clog burners and/or
pilot orifices.
CAUTION: DO NOT LIFT OR MOVE RANGE BY
DOOR HANDLES, OR BACKGUARD.
c.
Turn off all pilots and main gas valve of other gas
appliances.
d,
Turn off main gas valve at meter.
e.
Before connecting range, apply pipe thread
compound approved for LPG to all threads.
Use only a flexible connector to connect range to gas
supply at appliance pressure regulator using adaptors
supplied with connector. Regulator supplied with
range has 1/2" NPT female connection,
NOTE: It is recommended
to use a CSA certified
flexible
connector no longer than 36" (91.4 cm)
with a minimum BTU/HR rating of 88,200, and in
accordance with local codes.
See serial plate for type of gas range has been
manufactured for.
g.
Turn on main gas valve at meter, and relight pilots at
other gas appliances.
h,
Apply a non-corrosive
leak detection fluid to all joints
and fittings in the gas connection between the supply
line shut-off valve and the range. Include gas fittings
and joints in the range if connections were disturbed
during installation. Check for leaks! Bubbles
appearing around fittings and connections will indicate
a leak. If a leak appears, turn off supply line gas
shut-off valve, tighten connections, turn on the supply
line gas shut off valve, and retest for leaks,
CAUTION: NEVER CHECK FOR LEAKS WITH A
FLAME.
WHEN LEAK CHECK IS COMPLETE, WIPE OFF
ALL RESIDUE.
-6-

Advertisement

loading