INSTALLER:
LEAVE
THESE
INSTRUCTIONS
WITH THE APPLIANCE
INSTALLATION
MANUAL
Gas30-inch WideFree-Standing Range
PLEASE
KEEP THIS MANUAL
FOR FUTURE
REFERENCE
THE MANUAL
IS INTENDED
TO ASSIST IN THE INITIAL INSTALLATION AND ADJUSTMENTS
OF THE RANGE.
Only qualified personnel should
install or service this range.
Read "Safety
Instructions"
in the
Use & Care book before using
range.
Improper
installation,
adjustment,
alteration,
service,
maintenance
or
use of range can result in serious
injury or property
damage,
WARNING
i
• ALL RANGES CAN TIP AND
CAUSE INJURIESTO PERSONS.
i
INSTALL
ANTI-TIP
DEVICES
PACKED WITH RANGE.
1
FOLLOW ALL INSTALLATION
INSTRUCTIONS.
Your range may not be equipped
with
some of the features
referred ;€oin this
manual,
CLEARANCE
DIMENSIONS
Range may be installed with zero inches clearance
adjacent to (against) combustible construction at the rear
and on the sides below the cooktop. For complete
information in regard to the installation of wall cabinets
above the range and clearances to combustible wall
above the cooking top see the installation drawings. For
SAFETY CONSIDERATIONS
do not install a range in any
combustible cabinetry which is not in accord with the
installation drawings,
* NOTE: The 30 inch (76.2 cm) dimension may be
reduced to not less than 24 inches (61 cm) when the wall
cabinets in a domestic home are protected with fireproof
materials in accordance with American National
Standards - National Fuel Gas Code or in mobile homes
when they are protected with fireproof materials in
accordance with the Federal Standard for Mobile Home
Construction and Safety.
To eliminate the risk of burns or fire by reaching over
heated surface units, cabinet storage space located
above the surface units should be avoided. If cabinet
storage is to be provided, the risk can be reduced by
installing a range hood that projects horizontally a
minimum of 5 inches (13 cm) beyond the bottom of the
cabinets.
CAUTION:
This range has been designed
in
accordance
with the requirements
of various safety
agencies and complies with the maximum allowable
wood cabinet temperatures
of 194°F. If this range is
installed with cabinets that have a lower working
temperature
than 194°F, discoloration,
delamination
or melting may occur.
Contact Customer Service
for associated cabinet dimensions
and installation
accessories.
8101 P571-60
(02-06-02)

Advertisement

loading

Summary of Contents for Maytag MGR5775QDW - 30 Inch Gas Range

  • Page 1 INSTALLER: LEAVE THESE INSTRUCTIONS WITH THE APPLIANCE INSTALLATION MANUAL Gas30-inch WideFree-Standing Range PLEASE KEEP THIS MANUAL FOR FUTURE REFERENCE THE MANUAL IS INTENDED TO ASSIST IN THE INITIAL INSTALLATION AND ADJUSTMENTS OF THE RANGE. CLEARANCE DIMENSIONS Range may be installed with zero inches clearance adjacent to (against) combustible construction at the rear Only qualified personnel should and on the sides below the cooktop.
  • Page 2: Installation

    INSTALLATION DRAWINGS Note:Diagramis for newinstallation.Preexisting structures may needmodification for properinstallation. GAS AND ELECTRICAL SUPPLY SHOULD NOT CONVERGE. RECOMMENDED GAS SUPPLY AND/OR 120 VOLT GROUNDED FLUSH MOUNT ELECTRICAL OUTLET DO NOT GROUND ELECTRICAL SUPPLY TO GAS SUPPLY LINES. NOTE: TO ENSURE FLUSH TO WALL INSTALLATION GAS SERVICE INCLUDING SHUT-OFF VALVESHOULD NOT PROTRUDE MORE THAN 3"...
  • Page 3 (SEE NOTE ON fRONT PAGE) COMBUSTtBIE SURFACE 30" t76,? CM) O" (0 CW) CLEARANCE BETWEEN ADJACENT COMBUSTIBLE SURFACES AND THE BACK AND SIDES OF THE RANGE, BELOW THE COOKING SURFACE NOTE: COOKTOP 36" MUST BE FLUSH OR (91.5 CM) ABOVE COUNTERTOP COUNTER HEIGHT DIMENSION...
  • Page 4 ANTI-TIP DEVICE INSTALLATION INSTRUCTIONS Cement or Concrete Construction: NOTE: A risk of range tip over exists if the appliance is not installed in accordance with the installation Suitable screws for concrete construction can be instructions provided. The proper use of this device obtained at a hardware store.
  • Page 5 CONNECTING THE RANGE Electric Supply WARNING The appliance, when installed, must be electrically grounded in accordance with local codes or, in the absence of local codes, with the National Electrical Code, Gas leaks may occur in your system and result in a ANSl/NFPA 70.
  • Page 6 A GAS CUTOFF VALVE SHOULD BE PUT IN AN RecommendedGas SupplyConnections ACCESSIBLE LOCATION IN THE SUPPLY LINE AHEAD OF THE RANGE, FOR TURNING ON AND FLEXIBLE 3/8" TURNING OFF GAS SUPPLY. If range is to be SUPPLY STREET connected to house piping with flexible or semi-rigid LINE ELBOW metal connectors for gas appliances, CONNECTOR...
  • Page 7: Gas Conversion

    RANGE ADJUSTMENTS GAS CONVERSION Top Section - Electric Ignition SEE INSTRUCTIONS FOR GAS CONVERSION To operate, push and turn top burner knob to the LITE LOCATED ON THE BACK OF THE RANGE. position. The top burner will light. To turn OFF spark after the top burner has ignited, turn knob to Ht setting.