MR3P
Series Basic Serial Command Function Specification
‚ T .8.5 "10" [CR]
Abnormal power supply voltage
When the power supply voltage inside the projector reaches abnormal power
supply voltage, the power will be automatically turned off. The projector
returns "10"[CR] and cooling fan is also stopped at the time.
‚ T .8.6
"28" [CR]
Processing Cooling Down because of exceeding critical temperature. When
the temperature inside a projector is out of the operating temperature, it
automatically starts cooling down. Response is "28 (CR) at the time. Even if
when the temperature is processing low, the cooling down is executed.
‚ T .8.7 "08" [CR]
Abnormal Temperature
When the temperature does not go down after cooling down due to the
abnormal temperature, this is the Response. The projector keeps the Stan
By status.
‚ T .8.8 "88" [CR]
Normal status after recovering abnormal temperature.
When the temperature goes down after cooling down and moving to Stand
By status, this is the response.
This status keeps until the next operation. In short, when Power On is
executed, the temperature information is canceled, and works normal.
‚ T .8.9 "24" [CR]
Processing Power Save• E Cooling Down
Processing Power Save• E Cooling down by the power management function
in the e setting menu.
The control command is invalid.
This Power Save• E Cooling Down moves to Power Save after the cooling
down time.
STATUS• F No Signal
Response• F
No Signal
POWER SAVE• E COOLING DOWN
"00"
"24"
Soft
"04"
COOLING
Engineer Division
POWER SAVE
Page