Brother HL1060 - B/W Laser Printer Service Manual page 52

Service manual
Table of Contents

Advertisement

Note:
Follow instructions below when installing the cleaner ASSY HR.
• Put the cleaner ASSY HR on the heat roller.
• Rotate the hook of the cleaner ASSY HR as shown in the figure to fit it into the
fixing unit frame.
• Insert the cleaner lock into the fixing unit frame.
Fixing unit frame
(13)
Remove the bind B tight 3 x 10 screw securing the connector plate.
(14)
Remove the connector plate from the fixing unit frame and loosen the other bind B
tight 3 x 10 screw securing the fixing unit cover.
(15)
After removing the idle gear 16 from the fixing unit frame, the heat roller can be
removed. You can then remove the halogen heater lamp from the heat roller.
Note:
Never touch the surface of the halogen heater lamp.
Halogen heater lamp
(Blue 100V, Red 200V)
Bind B tight M3x10
Connector plate
Cleaner ASSY HR


Cleaner lock
Fig. 3.19
Heat roller
Idle gear 16
Fig. 3.20
III-13

Put the cleaner ASSY HR on
the heat roller and rotate it in this
direction to fit it into the hole.
Heat roller
Bind B tight M3x10
Fixing unit frame