Factory port threshold alarm configuration

Enter show config threshold CLI command to display threshold alarm configuration values. If the
ThresholdMonitoringEnabled parameter is disabled (False), none of the individual threshold monitoring
parameter settings can be applied.
Table 17

Port threshold alarm configuration defaults

Parameter
ThresholdMonitoringEnabled
CRCErrorsMonitoringEnabled
RisingTrigger
FallingTrigger
SampleWindow
DecodeErrorsMonitoringEnabled
RisingTrigger
FallingTrigger
SampleWindow
ISLMonitoringEnabled
RisingTrigger
FallingTrigger
SampleWindow
LoginMonitoringEnabled
RisingTrigger
FallingTrigger
SampleWindow
LogoutMonitoringEnabled
RisingTrigger
FallingTrigger
SampleWindow
LOSMonitoringEnabled
RisingTrigger
FallingTrigger
SampleWindow

Factory zoning configuration

Enter the show config zoning CLI command to display zoning configuration values.
Table 18

Zoning configuration defaults

Parameter
MergeAutoSave
DefaultZone
DiscardInactive
Default
False
True
25
1
10
True
25
0
10
True
2
0
10
True
5
1
10
True
5
1
10
True
100
5
10
Default
True
Allow
False
8/20q Fibre Channel Switch Installation and Reference Guide