System Fault Led Is Illuminated; Power-On Self Test Diagnostics; Heartbeat Led Blink Patterns; Internal Firmware Failure Blink Pattern - HP AK241A - StorageWorks 8Gb Simple SAN Connection Installation And Reference Manual

Fibre channel switch
Hide thumbs Also See for AK241A - StorageWorks 8Gb Simple SAN Connection:
Table of Contents

Advertisement

System fault LED is illuminated

The System Fault LED illuminates to indicate that a fault exists in the switch firmware or hardware. If the
System Fault LED illuminates, identify the Heartbeat LED error blink pattern and take the necessary actions.
See
"Heartbeat LED blink

Power-On self test diagnostics

The switch performs a series of tests as part of its power-up procedure. The POST diagnostic program
performs the following tests:
Checksum tests on the boot firmware in Programmable read-only memory (PROM) and the switch
firmware in flash memory
Internal data loopback test on all ports
Access and integrity test on the Application-specific integrated circuit (ASIC)
During the POST, the switch logs any errors encountered. Some POST errors are critical, others are not. The
switch uses the Heartbeat LED and the Logged-in LED to indicate switch and port status. A critical error
disables the switch so that it will not operate. A non-critical error allows the switch to operate, but disables
the ports that have errors. If two or more ports fail the POST, the entire switch is disabled. Whether the
problem is critical or not, contact your authorized maintenance provider.
If there are no errors, the Heartbeat LED blinks at a steady rate of once per second. If a critical error
occurs, the Heartbeat LED will show a blink pattern that indicates an error, and the System Fault LED will
illuminate. If there are non-critical errors, the switch disables the failed ports and flashes the associated
Logged-in LEDs. For more information, see

Heartbeat LED blink patterns

The Heartbeat LED indicates the operational status of the switch. When the POST completes with no errors,
the Heartbeat LED blinks at steady rate of once per second. When the switch is in maintenance mode, the
Heartbeat LED illuminates continuously. For more information, see
mode" on page 53. All other blink patterns indicate critical errors. In addition to producing a Heartbeat
error blink patterns, a critical error also illuminates the System Fault LED.
The Heartbeat LED shows an error blink pattern for the following conditions:
1 blink—Normal operation
2
blinks—Internal firmware failure blink
3
blinks—Fatal POST error blink
4
blinks—Configuration file system error blink
5
blinks—Over-temperature blink

Internal firmware failure blink pattern

An internal firmware failure blink pattern is 2 blinks followed by a two second pause. The 2-blink error
pattern indicates that the firmware has failed, and that the switch must be reset. Momentarily press and
release the Maintenance button to reset the switch.
48
patterns" on page 48.
pattern, page 49
pattern, page 49
2 seconds
"Heartbeat LED blink
patterns" on page 48.
"Recovering a switch using maintenance
pattern, page 48
pattern, page 49

Advertisement

Table of Contents
loading

This manual is also suitable for:

Storageworks sn6000 - fibre channel switch8/20q

Table of Contents