HP A7533A - Brocade 4Gb SAN Switch Base Release Note page 25

Hp storageworks fabric os 6.1.2b release notes (5697-0125, august 2009)
Hide thumbs Also See for A7533A - Brocade 4Gb SAN Switch Base:
Table of Contents

Advertisement

Fabric OS 6.1.2 fixes
Table 13
lists defects closed in the Fabric OS 6.1.2 firmware release.
Table 13 Fabric OS 6.1.2 closed defects
Closed defect summary
Host channel unable to access the CUP, even though path had just
been established. Receives Link Reject indicating "No Logical Path."
Switch verify/panic occurs during switch disable/switch enable for
unlicensed ports.
Full bandwidth over 2 ISLs on 2–Gb switches is not utilized, leading
to degraded performance.
Security daemon runs out of memory and triggers a switch panic, while
testing distributing ACL Database.
Frames rejected on trunked N_Ports after failback operation on HP
StorageWorks 8/24 SAN Switch when in Access Gateway mode and
interopmode 0 (Brocade native mode).
Switch panic is likely to occur in interopmode 2 (McDATA native mode)
with zone changes through WebTools.
Switch panic in FICON environment after repeated switchdisable
and switchenable and after logical path activation.
Default fmsmode enabled mihpto to be set to 15 seconds rather than
180 seconds, causing CUP commands to time out sooner than expec-
ted.
NSD termination observed while doing hafailover on all chassis.
Frame loss observed during stress testing of F_Port trunking with
bladedisable/hafailover/bladeenable/hafailover loop.
Traffic does not recover after blade is re-enabled.
In a routed fabric with a switch transmitting E_Port traffic to the F_Port,
the F_Port runs out of credit and is reset due to interswitch RSCN des-
ignated to translate domain from backbone switch getting routed by
mistake to lowest F_Ports.
Memory leak can occur due to E_Port constantly going on and off.
Switch panic occurs with Detected termination of process
iswitchd0 when PLOGI/FDISC have improper payload size.
Unexpected switch reboot in FICON setup due to memory corruption
issue, during plug/unplug of a FICON node.
Traffic isolation zone devices are not able to see others via the name
server because frames are F_RJTed; host cannot establish connectivity
to these devices.
Solution
Fixed in Fabric OS 6.1.2
Fixed in Fabric OS 6.1.2
Fixed in Fabric OS 6.1.2
Fixed in Fabric OS 6.1.2
Fixed in Fabric OS 6.1.2
Fixed in Fabric OS 6.1.2
Fixed in Fabric OS 6.1.2
Fixed in Fabric OS 6.1.2
Fixed in Fabric OS 6.1.2
Fixed in Fabric OS 6.1.2
Workaround: Add an ISL on the user
port that is lower than the lowest
F_Port on the switch.
Fixed in Fabric OS 6.1.2
Fixed in Fabric OS 6.1.2
Fixed in Fabric OS 6.1.2
Fixed in Fabric OS 6.1.2
Workaround: Reboot the switch.
Fixed in Fabric OS 6.1.2
HP StorageWorks Fabric OS 6.1.2b release notes
25

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ae370a - brocade 4gb san switch 4/12

Table of Contents