2
Enabling the GbE interface
To enable the physical ports
1. Connect and log in to the switch.
2. Enter the portCfgShow command with the blade slot number and GbE port number parameters
3. If Persistent Disable is set to ON, enter the portCfgPersistentEnable command with the slot
4. Enter the portCfgShow command with the slot number and GbE port number to verify that the
14
to display the Persistent Disable setting of the port.
switch:admin> portcfgshow 10/ge0
Mode:
Persistent Disable:
Ipif configuration:
Interface
IP Address
----------------------------------------------------------
0
30.0.130.100
Arp
configuration:
IP Address
Mac Address
------------------------------
Iproute Configuration:
IP Address
Mask
------------------------------------------------------
switch:admin>
number and GbE port number.
switch:admin> portcfgpersistentenable 10/ge0
port is persistently enabled.
The Persistent Disable settings is set to OFF.
switch:admin> portcfgshow 10/ge0
Mode:
Persistent Disable:
Ipif configuration:
Interface
IP Address
----------------------------------------------------------
0
30.0.130.100
Arp
configuration:
IP Address
Mac Address
------------------------------
Iproute Configuration:
IP Address
Mask
------------------------------------------------------
switch:admin>
ISCSI
ON
NetMask
255.255.0.0
Gateway
ISCSI
OFF
NetMask
255.255.0.0
Gateway
MTU
1500
Metric
MTU
1500
Metric
iSCSI Gateway Service Administrator's Guide
53-1000603-01