Checking For A Point-To-Point Initialization Failure; Correcting A Port That Has Come Up In The Wrong Mode - Brocade Communications Systems A7533A - Brocade 4Gb SAN Switch Base Troubleshooting Manual

Brocade fabric os troubleshooting and diagnostics guide v6.2.0 (53-1001187-01, april 2009)
Hide thumbs Also See for A7533A - Brocade 4Gb SAN Switch Base:
Table of Contents

Advertisement

3. Skip point-to-point initialization by using the portCfgLport Command.

Checking for a point-to-point initialization failure

1. Enter the switchShow command to confirm that the port is active and has a module that is
2. Enter the portLogShow or portLogDump commands.
3. Verify the event area for the port state entry is pstate. The command entry AC indicates that
4. Skip over the loop initialization phase.

Correcting a port that has come up in the wrong mode

1. Enter the switchShow command.
2. Check the output from the switchShow command and follow the suggested actions in
Fabric OS Troubleshooting and Diagnostics Guide
53-1001187-01
The switch changes to point-to-point initialization after the LISA phase of the loop initialization.
This behavior sometimes causes trouble with old HBAs.
synchronized.
If a fabric device or another switch is connected to the switch, the switch port must be online.
the port has completed point-to-point initialization.
switch:admin> portlogdumpport 4
time
task
-------------------------------------------------
11:38:21.726
INTR
After becoming an active port, the port becomes an F_Port or an E_Port depending on the
device on the opposite side. If the opposite device is a fabric device, the port becomes an
F_Port. If the opposite device is another switch, the port becomes an E_Port.
If there is a problem with the fabric device, enter the portCfgGPort to force the port to try to
come up as point-to-point only.
TABLE 4
SwitchShow output and suggested action
Output
Suggested action
Disabled
If the port is disabled (for example, because persistent disable or security reasons),
attempt to resolve the issue and then enter the portEnable or portCfgPersistentEnable
command.
Bypassed
The port may be testing.
Loopback
The port may be testing.
E_Port
If the opposite side is not another switch, the link has come up in a wrong mode. Check the
output from the portLogShow or PortLogDump commands and identify the link initialization
stage where the initialization procedure went wrong.
F_Port
If the opposite side of the link is a private loop device or a switch, the link has come up in a
wrong mode. Check the output from portLogShow or PortLogDump commands.
event
port cmd
args
pstate
4
AC
3
Link failures
Table
4.
27