FULL-RANGE
INPUT SIGNAL
(FULL-RANGE
INPUT SIGNAL)
26
5. Install and refasten the amplifier panel, securely
Section 9
Block Diagram
This is a block diagram of an NT Full-Range with an NT subwoofer. A full-range
input signal is connected to the full-range loudspeaker and looped through to the
subwoofer (solid lines). Alternately, the full-range input can be connected to the
subwoofer and looped through to the full-range loudspeaker (dotted lines).
DSP PC
HPF
BOARD
THRU
EQ
LIMIT
DELAY
INPUT A/D
IN
LPF
EQ
LIMIT
DELAY
NT FULL-RANGE
DSP PC
BOARD
THRU
INPUT A/D
IN
NT SUBWOOFER
tightening all screws.
AMPLIFIER
&
POWER SUPPLY
ASS'Y
D/A
AMP
500 W @ 4 OHM
AMP
D/A
1000 W @ 4 OHM
AMPLIFIER
POWER SUPPLY
ASS'Y
AMP
EQ
DELAY
1000 W @ 4 OHM
LPF
D/A
LIMIT
AMP
1000 W @ 4 OHM
HF
LF
&
LF
LF