12.2.1 Diskless Configuration Support
The system supports diskless configuration with no storage controller (SAS 6/iR, PERC 6i, PERC H200,
or PERC H700) installed in the system. A 3.5‖ hard-drive backplane is still installed in this
configuration.
12.2.2 Hard Drive LED Indicators
Each disk drive carrier has two LED indicators visible from the front of the system. One is a green LED
for disk activity and the other is a bicolor (green/amber) LED for status information. The activity LED
is driven by the disk drive during normal operation. The bicolor LED is controlled by the storage
enclosure processor (SEP) device on the backplane. Both LEDs are used to indicate certain conditions
under direction of a storage controller.
For more information, see the Hard-Drive Indicator Patterns section in the About Your System
chapter in the Dell PowerEdge R710 Systems Hardware Owner's Manual on Support.Dell.com.
12.3 RAID Configurations
See Table 11 for information on factory RAID configurations. For information on additional
configurations, visit Dell.com.
Config
Type
No HDD
SAS or
SATA—No
RAID
SAS or
SATA—
RAID
SAS or
SATA—
RAID
PowerEdge R710 Technical Guide
Factory RAID Configurations
Table 11.
Configs
Description
0
NZC
No controller/No hard drive
Integrated SAS/SATA (SAS 6/iR,
1
MSS
PERC 6/i, PERC H200, or PERC
H700), No RAID
Integrated SAS/SATA RAID 0
(SAS 6/iR, PERC 6/i, PERC
2
MSSR0
H200, or PERC H700)
Integrated SAS/SATA RAID 1
(SAS 6/iR, PERC 6/i, PERC
3
MSSR1
H200, or PERC H700)
Integrated SAS/SATA RAID 5
4
MSSR5
(PERC 6/i, PERC H700)
Integrated SAS/SATA RAID 10
5
MSSR10
(PERC 6/i, PERC H700)
Integrated SAS/SATA RAID
6
MSSR0/R0
0/RAID 0 (SAS 6/iR, PERC 6/i,
PERC H200, or PERC H700)
Non-Mixed drives
all SATA, all SAS, or
all SSD
Min HDD
Max HDD
2.5‖ = 0
2.5‖ = 0
2.5‖ = 1
2.5‖ = 8
3.5‖ = 1
3.5‖ = 6
2.5‖ = 2
2.5‖ = 8
3.5‖ = 2
3.5‖ = 6
2.5‖ = 2
2.5‖ = 2
3.5‖ = 2
3.5‖ = 2
2.5‖ = 3
2.5‖ = 8
3.5‖ = 3
3.5‖ = 6
2.5‖ = 4
2.5‖ = 8
3.5‖ = 4
3.5‖ = 6
2.5‖ =
1 + 1
2.5‖ = 8
3.5‖ =
3.5‖ = 6
1 + 1