Maximum Input Amps; Energy Smart Enablement; Energy Star Compliance; Acoustics - Dell External OEMR R710 Technical Manual

2-socket 2u rack server with the performance of intel xeon processors
Table of Contents

Advertisement

Dell

5.7 Maximum Input Amps

Maximum input current (High Output—870W):
12 A @ 90 VAC
6 A @ 180 VAC
Maximum input current (Energy Smart—570W):
7.8 A @ 90 VAC
3.9 A @ 180 VAC

5.8 Energy Smart Enablement

The 11G family of PowerEdge servers implements aspects of Dell's Energy Smart strategy. This
strategy offers the following:
Energy Smart components on a portfolio level, such as high-capacity and Energy Smart power
supplies
Systems with either a lowest power footprint configuration or a best performance per watt
configuration
Energy Smart components (such as DIMMs or hard drives) selected without cherry picking or
screening individual manufacturer's components based on energy consumption

5.9 Energy Star Compliance

®
ENERGY STAR
qualified configurations can be accessed from the
landing page on Dell.com.

5.10 Acoustics

The acoustical design of the PowerEdge R710 reflects adherence to Dell's high sound quality
standards. Sound quality is different from sound power level and sound pressure level in that it
describes how humans respond to annoyances in sound, like whistles, hums, etc. One of the sound
quality metrics in the Dell specification is prominence ratio of a tone as shown in Table 7.
Typical Configuration @ 23 ± 2 °C
CPUs
HDDs
2
4
The acoustical specification for the R710 is Category II-D.
Definitions
Idle: Reference ISO7779 (1999) definition 3.1.7; system is running in its OS but no other specific
activity.
Stressed Processor: An operating mode per ISO7779 (1999) definition 3.1.6. The software
SPECPower_ssj2008 is utilized to stress the processors. SPECPower is set to 50% loading.
LwA – UL: The upper limit sound power level (LwA) calculated per section 4.4.2 of ISO 9296 (1988)
and measured in accordance to ISO 7779 (1999).
PowerEdge R710 Technical Guide
Acoustical Performance
Table 7.
Operating Mode
Power
Optical
Supplies
Drive
Idle
2
1
Stressed
ENERGY STAR Compliance results
L
-UL
L
Prominent
WA
pA
Tones
(Bels)
(dBA)
5.5
39
None
5.9
42
None
25

Advertisement

Table of Contents
loading

This manual is also suitable for:

R710 - poweredge - 4 gb ramPoweredge r710