6.3.5
Exiting the Intel
To exit the utility:
From the utility main menu, select 4. Exit, and then press <Enter>. The
1.
following warning message appears.
2.
Press <Y> to exit or press <N> to return to the utility main menu.
6.3.6

Rebuilding the RAID

This option is only for the RAID 1 set.
Rebuilding the RAID with other non-RAID disk
If any of the SATA hard disk drives included in the RAID 1 array failed, the system
displays the status of the RAID volume as "Degraded" during POST. You can
rebuild the RAID array with other installed non-RAID disks.
To rebuild the RAID with other non-RAID disk:
1.
At the prompt, press <Ctrl> + <I> to enter the Intel Rapid Storage Technology
option ROM utility.
2.
If there is a non-RAID SATA Hard Disk available, the utility will prompt to
rebuild the RAID. Press <Enter>, and then use up/down arrow keys to select
the destination disk or press <ESC> to exit.
"Degraded" volume and disk available for rebuilding detected. Selecting
a disk initiates a rebuild. Rebuild completes in the operating system.
Select the port of destination disk for rebuilding (ESC to exit):
P o r t
X
XXXXXXXXXXX
Select a destination disk with the same size as the original hard disk.
ASUS RS720Q-E7/RS12, RS724Q-E7/RS12, RS726Q-E7/RS12
Rapid Storage Technology utility
®
[
CONFIRM EXIT
Are you sure you want to exit? (Y/N):
[
DEGRADED VOLUME DETECTED
D r i v e
M o d e l
XXXXXXXX
[↑↓]-Previous/Next
]
]
S e r i a l
#
XX.XGB
[ENTER]-Select
[ESC]-Exit