Table 6-8 Informational Codes
Event code Event code name
0x601
SP Power Up
0x602
Drive Enabled
0x603
Rebuild Started
0x604
Rebuild Completed
0x606
Unit Shutdown for
Trespass
0x607
Unit Shutdown for
Change Bind
0x608
Drive Ready
0x609
Format Started
0x610
Format Failed
0x611
SP PROM Rev
0x613
CRU Equalize Started
0x614
CRU Equalize Completed The SP has completed a Rebuild/Equalize operation.
0x615
CRU Equalize Aborted
0x616
Flare Installed
0x617
Code Installed to Drive
Description
The SP is powered up and ready for I/O. This field also shows
the revision of microcode (Licensed Internal Code) and the
amount of SP memory in MB, in hexadecimal. For example,
(SP Powerup); Rev 0x00080A01 0x00000020 means code
revision 8.10.01 and 32 MB of memory.
The unit this drive belongs to is ready for normal host I/O.
The background rebuild process has begun rebuilding the
data on this drive.
The background rebuild process has completed rebuilding the
data on this drive.
The unit of which this drive is a member has been shut down
by this SP at the request of the peer SP, due to a Trespass
operation.
The LUN this module belongs to has been shut down by this
SP in order to change its operating parameters. This
shutdown is needed only when the SP is operating in Target
Addressing Mode.
The specified drive is powered up and physically ready for
use.
The given FRU is being formatted.
The format started on the disk module was unsuccessful so
the disk can not be used by the SP. Make sure the disk
module is a valid model. If it is valid, consult your Hewlett-
Packard support representative for recovery service.
Notes PROM revision, the extended status identifies the SP's
ID. This message is logged once at the completion of every
powerup.
The SP has started a Rebuild/Equalize operation.
The SP has aborted a Rebuild/Equalize operation.
Extended status identifies revision information. This message
is logged once when new flare code is installed.
Extended status identifies revision information. This message
is logged, once for each updated drive, when new drive code
is installed. Note that the revision information for drives
consists of 4 ASCII characters (for example, code "0123" will
appear as 0x30313233).
Unsolicited Event Log