WIRING
To protect against fire and electrocution:
• DISCONNECT power and battery BEFORE
installing or servicing operator.
For continued protection against fire:
• Replace ONLY with fuse of same type and
rating.
4
CONNECT BATTERIES
1
Connect the battery wires to the
J15 plug on the control board.
2
+
-
Turn ON AC power to the
BATT
DC
operator.
3
Turn ON the AC power switch on
the operator.
3
POWER WIRING
This operator can be wired for either 120 Vac or 240 Vac or a
solar panel (not provided). These instructions show a 120 Vac
application. For information regarding a 240 Vac or solar
application refer to the installation manual.
1
Turn off the AC power from the main
power source circuit breaker.
2
Run the AC power wires to the
operator.
3
Connect the green wire to the earth
ground rod and AC ground using a
wire nut. NOTE: The earth ground
rod can be grounded to the chassis.
4
Connect the white wire to NEUTRAL
using a wire nut.
5
Connect the black wire to HOT using
a wire nut.
01-35590
ALARM
RESET
+
Red Wire
Jumper
Junction Box
1
WIRE THE ENTRAPMENT PROTECTION DEVICES
Connect the entrapment protection device to the EYES EDGE terminal on the control
board.
• Close Photoelectric Sensor Entrapment Protection: Connect wires from the
photoelectric sensors to the Inputs on the CLOSE EYES/INTERRUPT terminal.
• Close Edge Entrapment Protection: Connect wires from the entrapment protection
device to the Inputs on the CLOSE EDGE terminal.
• Open Entrapment Protection: Connect wires from the entrapment protection device
to the Inputs on the OPEN EYES/EDGE terminal.
AC Power Switch
2
EARTH GROUND ROD
1
Install the earth ground rod within 3 feet
of the operator.
2
Run wire from the earth ground rod to the
operator.
Check national and local
codes for proper depth
©2011 The Chamberlain Group, Inc.
All Rights Reserved
INITIAL LIMITS AND FORCE ADJUSTMENT
5
1
Press and release the SET OPEN and SET CLOSE buttons simultaneously to enter limit setting mode.
2
Press and hold one of the MOVE GATE buttons to move the gate to the
open or close limit.
PRESS &
3
RELEASE
TO BEGIN
Press and release the SET CLOSE or SET OPEN button
depending on which limit is being set.
4
TO BEGIN
LIMIT
Press and hold one of the MOVE GATE button to move the
PRESS &
RELEASE
gate to the other limit.
TO BEGIN
LIMIT
RESET
ALARM
MOVE
SETUP
GATE
5
SET OPEN SET CLOSE
INPUT POWER
STATUS:
5
OFF
Press and release the SET CLOSE or SET OPEN button depending on which
PRESS &
RELEASE
limit is being set.
TO BEGIN
LIMIT
6
Cycle the gate open and close. This automatically sets the force.
When limits are set properly the operator will automatically exit limit setting mode.
FINE TUNE THE FORCE
6
The FORCE DIAL on the control board is used for fine tuning the force. The force setting should be high enough that
the gate will not reverse by itself nor cause nuisance interruptions, but low enough to prevent serious injury to a
person. The force setting is the same for both the open and close gate directions.
1
Open and close the gate with the test buttons.
2
If the gate stops or reverses before reaching the fully
open or closed position, increase the force by turning the
force control slightly clockwise.
3
Perform the "Obstruction Test" after every force setting adjustment (see below).
OBSTRUCTION TEST
7
1
Open and close the gate with the test buttons, ensuring that the gate is stopping at the proper open and close limit
positions.
2
Place a solid object between the open gate and a rigid structure. Ensure that the gate, the solid object, and the rigid
structure can withstand the forces generated during this obstruction test.
3
Run the gate in the close direction. The gate should stop and reverse upon contact with the solid object. If the gate
does not reverse off the solid object, reduce the force setting by turning the force control slightly counter-clockwise.
The gate should have enough force to reach both the open and close limits, but MUST reverse after contact with a
solid object.
4
Repeat the test for the open direction.
PROGRAMMING
8
2
1
Press the remote control button for the
Press and release the LEARN
desired function. The
button (operator will beep
operator will automatically
and green XMITTER LED will
exit learn mode (operator
light).
will beep and green
XMITTER LED will go out)
if programming is
successful.
XMITTER
NETWORK
NETWORK
ALARM
RESET
60
180 MIN
MAX
BATT LOW