MAINS OPERATION & RESULTING TEMPERATURES
MAINS OPERATION & RESULTING POWER AMP TEMPERATURES
The following tables are useful in determining power supply and cabling requirements.
The power drawn from the mains network is converted into acoustic output to feed the connected
loudspeaker systems plus heat. The difference between drawn power and dispensed power is referred
to as leakage power or dissipation (
remain inside of a rack-shelf and needs to be diverted using appropriate measures. The following table
is meant as auxiliary means for calculating temperatures inside of rack-shelf systems/cabinets and the
ventilation efforts necessary.
The column "Pd" lists the leakage power in relation to different operational states. The column "BTU/
hr" shows the dispensed heat amount per hour.
Xa 4000
idle
Max. Output Power @ 8Ω
Max. Output Power @ 4Ω
1/3 Max. Output Power @ 4Ω
1/8 Max. Output Power @ 4Ω
1/8 Max. Output Power @ 4Ω
1/8 Max. Output Power @ 4Ω
Normal Mode (-10dB) @ 4Ω
Rated Output Power (0dB) @ 4Ω
Alert (Alarm) Mode (-3dB) @ 4Ω
1/3 Max. Output Power @ 2Ω
1/8 Max. Output Power @ 2Ω
1/8 Max. Output Power @ 2Ω
(1) Sine Signal Modulation (80Hz/1kHz)
(3) 1BTU = 1055.06J = 1055.06Ws
(5) Pd = Leakage Power
The following factors allow direct proportional calculation of the power consumption for different mains
supply voltages:
100V = 2.3; 120V = 1.9; 220V = 1.05; 240V = 0.96
). The amount of heat resulting from power dissipation might
P
d
U mains
I mains
[V]
[A]
230V
1
230V
10,6
(1)
230V
18,2
(1)
230V
10,3
(1)
230V
4,5
(1)
230V
5,5
(2)
254V
5,5
(2), (4)
230V
4,1
(1)
230V
17,2
(1)
230V
12,3
(1)
230V
16,7
(2)
230V
7,2
(1)
230V
8,8
(2)
(2) Band-limited Pink Noise
(4) 10% Mains Over Voltage
9
P mains
P out
SUB+TOP
[W]
[W]
80
-
1640
600+500
3000
1100+900
1580
366+300
610
137+113
790
137+113
840
166+137
550
110+90
2800
1000+800
1920
500+400
2720
600+533
1050
225+200
1260
225+200
Pd (5)
BTU/hr (1)
[W]
80
273
540
1840
1000
3410
914
3120
360
1230
540
1840
537
1830
350
1190
1000
3410
1020
3480
1587
5420
625
2130
835
2850