Wsw33 - Brother IntelliFax-3550 Service Manual

Facsimile equipment
Table of Contents

Advertisement

Selector
No.
1
Detection threshold level for
voice signals inputted via the
|
network in the built-in TAD
operation
3
4
First communications speed
choice for PCI
5
Report output of polled trans-
6
mission requests
7
Not used.
8
NOTE: The WSW33 is applicable to those models equipped with a built-in TAD.
Selectors 4 and 5: First communications speed choice for PCI
These selectors are used to set the first communications speed choice with which the equip-
ment attempts to synchronize the data transmission via the PC interface. If the synchroniza-
tion fails, the equipment automatically steps down to the next lowest speed.
Selector 6:
Report output of polled transmission requests
This function does not apply in the U.S.A. versions.

WSW33

(Function setting 11)
Function
V – 44
Setting and Specifications
No. 1
2
3
0
0
0
:
-42.5 dBm
0
0
1
:
-44.0 dBm
0
1
0
:
-45.5 dBm
0
1
1
:
-47.0 dBm
1
0
0
:
-48.5 dBm
1
0
1
:
-50.0 dBm
1
1
0
:
-51.5 dBm
1
1
1
:
-53.0 dBm
No. 4
5
0
0
:
14,400 bps
0
1
:
12,000 bps
1
0
:
9,600 bps
1
1
:
7,200 bps
0: YES
1: NO
(A)
(B)
(C)
(D)
(E)
(F)
(G)
(H)