4.2 Setting commands
Most of the HD-R1's settings can be configured remotely. Their parameter IDs and acceptable values are defined in
the following tables. With some exceptions, all parameters may both be set and queried with a command. Although
they are not case sensitive, blank spaces within parameter IDs and setting values must be exactly as shown.
The format for setting commands is the same as for others as shown in the example below.
Parameter ID
Character
Auto Cue (example)
string
The following can be set and queried at any time.
Parameter ID
Num Of Folders
Num Of Playlists
Repeat
Auto Ready
Auto Cue
Channels
WAV Sample Width
TASCAM HD-R1 RS-232C Protocol Specifications
Command
Setting value
=: set value
<Value>: as necessary
?: query
Valid values
Total number of folders (query only)
Total number of playlists (query only)
Off
On
Off
On
Off
-72 dBFS
-66 dBFS
-60 dBFS
-54 dBFS
-48 dBFS
-42 dBFS
-36 dBFS
-30 dBFS
-24 dBFS
Mono Left
Mono Right
Mono Summed
Stereo
16 Bits
24 Bits
9
End Marker
LF (or CR+LF)
TEAC Corporation