1. Inspecting the magazine
1 REMOVE FUEL CELL and BATTERY.
2 Clean the magazine. Remove dust and
wooden chips which may have
accumulated in the magazine. Lubricate
it with Hitachi Gas tool lubricant.
MAINTENANCE
DANGER
Never use and
test in presence
of
flammable
liquids or gases.
Keep away from
ignition source.
No smoking.
CAUTION
Check that the nail feeder slides
smoothly by pulling it with finger.
If not smooth, nails can be driven at an
irregular angle and hurt someone.
2. Storing
120°F MAX
(50°C)
English
Cloth
DANGER
Store
Nailer
properly with fuel
cell and battery
removed.
The fuel cell is an
a e r o s o l
dispensers with
f l a m m a b l e
contents.
When not in use,
the Nailer, fuel
cell and battery
should be stored
in tool case and in
a dry place.
Store indoors at
t e m p e r a t u r e
below
120°F
(50°C).