1-6. Insulation Tests
On completion of disassembly and repair, measure the insulation resistance and dielectric strength.
Insulation Resistance: 7M
Dielectric Strength:
AC 4,000 V/1 minute, with no abnormalities ............220 V - 240 V (and 110 V for U.K. products)
AC 2,500 V/1 minute, with no abnormalities ............110 V - 115 V (except U.K. products)
1-7. No-Load Current Values
After 30 minutes of no-load operation, current values should be as follows.
100 V
115 V
220 V
230 V
240 V
or more with DC 500 V Megohm Tester
111111111 Less than 2 A
..........Less than 1 A
12