turn the switch on, then back off, then wait between 11 and 14 seconds and turn the switch back on. When the lights come back on, they should enter
program #1, and be synchronized.
Programs
When in Universal ColorLogic mode (default), the Universal ColorLogic/CrystaLogic light has the capability to display 17 different programs; 10 fixed colors
and 7 color-changing shows. These programs are advanced using power-cycling (quickly powering the lights on, then off, then back on). The programs
are listed below:
1.
Show-Voodoo Lounge
2.
Fixed-Deep Blue Sea
3.
Fixed-Royal Blue
4.
Fixed-Afternoon Skies
5.
Fixed-Aqua Green
6.
Fixed-Emerald
7.
Fixed-Cloud White
8.
Fixed-Warm Red
9.
Fixed-Flamingo
10. Fixed-Vivid Violet
11. Fixed-Sangria
12. Show-Twilight
13. Show-Tranquility
14. Show-Gemstone
15. Show-USA
16. Show-Mardi Gras
17. Show-Cool Cabaret
Refer to the included color card as a quick reference to the available programs.
Networking
Using a ColorLogic modem AQL-COLOR-MODHV and Coupler LKBUN1000, owners of Hayward Pro Logic PS pool/spa controllers can network their LS-
CUN11xxx and/or LPCUN11xxx Universal ColorLogic light(s) allowing them to fully control the color, speed, motion and brightness of preset light shows.
If the lights will be networked, refer to the AQL-COLOR-MODHV ColorLogic Network module for operation instructions.
If you have a problem with your Hayward Universal ColorLogic/CrystaLogic light, please try the following tips before calling for service:
PROBLEM: Light will not advance to the next program when it is power-cycled (turned "off" and then back "on").
SOLUTION: Do not power-cycle the switch too rapidly. Leave it off for at least 1 second before turning it back on.
PROBLEM: Light goes to white whenever it is power-cycled (turned "off" and then back "on").
SOLUTION: Be sure that you power-cycle the light for less than 10 seconds.
PROBLEM: Multiple lights are not correctly synchronized.
SOLUTION: Verify that the Universal ColorLogic/CrystaLogic light is in the proper mode (page 12). Follow the steps in these instructions to re-synchronize
the lights.
PROBLEM: Light will not come on.
SOLUTION: Check input power to transformer and then light. Check ground fault and reset if necessary.
PROBLEM: Light will not come on or light cycles on and off.
SOLUTION: Automatic thermal switch may be cycling due to excessive temperatures. Check pool or spa water temperature.
PROBLEM: Light does not function properly, or does not function at all.
SOLUTION: Verify that your pool/spa controller is not "dimming" the light.