Install Wiring using a Wallmount Transformer
A suitable transformer must be installed which is agency listed for low-voltage swimming pool and spa lights (Hayward LTBUY11300, Intermatic
model
®
PX100/PX300, or equivalent). The transformer must be rated at or above the total wattage used by all attached light fixtures. Up to four Universal Col-
orLogic/CrystaLogic LED lights (three pool lights max.) can be connected to a single Hayward LTBUY11300 transformer.
Run conduit from the junction box to the low voltage transformer, pool/spa controller, or switch box. Snake 2 wires through the conduit from the junction
box to the power supply. If multiple lights are being installed, run additional conduit/wires from the junction box to the additional junction box(es). When
wiring multiple lights to the same 12 volt source, do not exceed the transformers's total rated wattage. Refer to the manufacturer's specifications and
instructions for run length and wiring size. Use wire nuts to connect the field-installed wiring to the light fixture cord in the junction box. Connect the
ground wires to the ground terminal connections inside the junction box.
9