Vcore; Vocp & Ovp Test-Ver0.91; Vcore Ocp & Ovp Test-Ver0.93; Vcore Ocp & Ovp Test-Ver1.0 - Biostar P4 TDG Engineering Validation Test Report

P4tdg compatibility test report
Hide thumbs Also See for P4 TDG:
Table of Contents

Advertisement

M/B
VID Setting
Electronic Loading
O.C.P test
Over 60A
M/B
VID Setting
Electronic Loading
O.C.P test
Over 60A
M/B
VID Setting
Electronic Loading
O.C.P test
Over 60A
M/B
VID Setting
Electronic Loading
O.C.P test
Over 60A
67
V
OCP & OVP TEST-Ver0.90
CORE
Test Environment
TDG/0.90
1.75
Chroma 63030
Pass/Fail
Pass
V
OCP & OVP TEST-Ver0.91
CORE
Test Environment
TDG/0.91
1.75
Chroma 63030
Pass/Fail
Pass
V
OCP & OVP TEST-Ver0.93
CORE
Test Environment
TDG/0.91
1.75
Chroma 63030
Pass/Fail
Pass
V
OCP & OVP TEST-Ver1.0
CORE
Test Environment
TDG/1.0
1.75
Chroma 63030
Pass/Fail
Pass
Power Supply
PWM
Engineer Signature
O.V.P test
2.18
Power Supply
PWM
Engineer Signature
O.V.P test
2.28
Power Supply
PWM
Engineer Signature
O.V.P test
2.28
Power Supply
PWM
Engineer Signature
O.V.P test
2.28
ST-300BLV
Hip 6302
Panda
Pass/Fail
Pass
DELTA DPS-300KB
Hip 6302
Panda
Pass/Fail
Pass
DELTA DPS-300KB
Hip 6302
Panda
Pass/Fail
Pass
DELTA DPS-300KB
Hip 6302
Panda
Pass/Fail
Pass