Core Ocp & Ovp Test-Ver1.0; Core Ocp & Ovp Test-Ver1.1; Core Ocp & Ovp Test-Ver1.2 - Biostar M7TDE Datasheet

Engineering validation test report
Hide thumbs Also See for M7TDE:
Table of Contents

Advertisement

M/B
VID Setting
Electronic Loading
O.C.P test
43.5A
Comments:
M/B
VID Setting
Electronic Loading
O.C.P test
50A
Comments:
M/B
VID Setting
Electronic Loading
O.C.P test
50A
Comments:
62
V
OCP & OVP TEST-Ver1.0
CORE
Test Environment
TDE/1.0
1.75V
Chroma 63030
Pass/Fail
Pass
V
OCP & OVP TEST-Ver1.1
CORE
Test Environment
TDE/1.1
1.75V
Chroma 63030
Pass/Fail
Pass
V
OCP & OVP TEST-Ver1.2
CORE
Test Environment
TDE/1.2
1.75V
Chroma 63030
Pass/Fail
Pass
Power Supply
PWM
Engineer Signature
O.V.P test
2.02
Power Supply
PWM
Engineer Signature
O.V.P test
2.17
Power Supply
PWM
Engineer Signature
O.V.P test
2.17
ST-300BLV
HIP6302
Yi-Hung
Pass/Fail
Pass
Enlight HPC-250
HIP6302
Panda
Pass/Fail
Pass
Enlight HPC-250
HIP6302
Panda
Pass/Fail
Pass