Core Ocp & Ovp Test-Ver0.90; Core Ocp & Ovp Test-Ver1.0 - Biostar U8568 Test Report

Engineering validation test report
Hide thumbs Also See for U8568:
Table of Contents

Advertisement

M/B
VID Setting
Electronic Loading
O.C.P test
Over 60A Pass/Fail
Comments:
M/B
VID Setting
Electronic Loading
O.C.P test
Over 60A Pass/Fail
Comments:
59
V
OCP & OVP TEST-Ver0.90
CORE
Test Environment
Vxd/0.90
1.75V
Chroma 63030
Pass
V
OCP & OVP TEST-Ver1.0
CORE
Test Environment
U8568/1.0
1.75V
Chroma 63030
Pass
Power Supply
PWM
Engineer Signature
O.V.P test 2.35V
Power Supply
PWM
Engineer Signature
O.V.P test 2.35V
Enlight hpc-250
Hip6302cb
K.E.Y.
Pass/Fail
Pass
Enlight hpc-250
Hip6302cb
K.E.Y.
Pass/Fail
Pass

Advertisement

Table of Contents
loading

Table of Contents