Vcore Ocp & Ovp Test-Ver0.9; Vcore Ocp & Ovp Test-Ver1.0 - Biostar M7SXG Datasheet

Engineering validation test report
Hide thumbs Also See for M7SXG:
Table of Contents

Advertisement

M/B
VID Setting
Electronic Loading
O.C.P test
57A
M/B
VID Setting
Electronic Loading
O.C.P test
57A
54
V
OCP & OVP TEST-Ver0.9
CORE
Test Environment
SXG/0.9
1.75v
Chroma 63030
Pass/Fail
Pass
V
OCP & OVP TEST-Ver1.0
CORE
Test Environment
SXG/1.0
1.75v
Chroma 63030
Pass/Fail
Pass
Power Supply
PWM
Engineer Signature
O.V.P test
2.05V
Power Supply
PWM
Engineer Signature
O.V.P test
2.05V
ST-300BLV
HIP6302
Yi-Hung
Pass/Fail
Pass
ST-300BLV
HIP6302
Yi-Hung
Pass/Fail
Pass