GE DBVH520GJ Installation Instructions Manual page 3

Installation instructions
Hide thumbs Also See for DBVH520GJ:
Table of Contents

Advertisement

3 RECONNECTING GAS
Listed connector ANSI Z21.24 / CSA 6.10
NEW METAL
FLEXIBLE GAS
LINE CONNECTOR
ADAPTER
ELBOW
ITEMS NOT SUPPLIED
Note: The connector and fittings are designed for use only on the
original installation and are not to be reused for another appliance
or at another location. Keep flare end of adaptor free of grease, oil
and thread sealant.
Caution: Use adapters as shown. Connector nuts must not be
connected directly to pipe threads.
APPLY PIPE COMPOUND
TO THE ADAPTER AND
DRYER GAS INLET.
Tighten the flexible
gas line using two
adjustable wrenches.
Installation Instructions
ADAPTER
1/8" NPT PIPE
PLUG FOR
CHECKING GAS
INLET PRESSURE
SHUT-OFF
VALVE
3/8" NPT
PIPE SIZE
AT LEAST 1/2"
APPLY PIPE COMPOUND
TO ALL MALE THREADS.
Tighten all connections using two adjustable wrenches.
Do not overtorque gas connections!
4 LEAK TEST
WARNING - NEVER USE AN OPEN
FLAME TO TEST FOR GAS LEAKS.
OPEN
GAS VALVE.
Check all connections for leaks with soapy solution or equivalent.
Apply soap solution. Leak test solution must not contain ammo-
nia which could cause damage to the brass fittings. If leaks are
found, close valve, retighten the joint, and repeat the soap test .